"We run a bakery and patisserie in Montrouge, with a 42 m² sales floor and a 30 m² bakehouse at the back. In 2023, an installer fitted two 3.5 kW wall-mounted split units, one in the shop and one above the production kitchen worktop. Since then, the shop unit ices up as soon as it hits 32 °C outside, and the kitchen one stopped for good in August — the refrigeration engineer is talking about the compressor. And the refrigerated display cases are consuming more than ever. We're being offered the same thing, only more powerful."
This is not a question of capacity. A food shop is not just another commercial space: it is a building that generates heat continuously, and in which air conditioning has to coexist with commercial refrigeration, cooking processes and a door that opens several hundred times a day. Comfort equipment installed on top of all that will not last two seasons.
This article does not revisit topics already covered on this blog — homeowners' association consents, outdoor unit noise, the cost of a repair call, mandatory servicing, commercial leases. It describes the working method specific to food shops in the Paris region: a bakery with a bakehouse, a patisserie with a production kitchen and a cold room, a butcher's and delicatessen, a cheese shop, a caterer, a chocolate shop, a greengrocer, a wine merchant with a back room, a snack bar or sandwich shop. The enquiries all look alike: a living-room machine fitted to a production space.

Three spaces, three trades: why a single quote is not enough
In most of the food shops we visit, there are in fact three rooms with contradictory needs under the same lease.
The sales floor. Goal: comfort for customers and staff, product holding in open display cases, and humidity control. The thermal load varies through the day, spikes at peak hours, and the entrance door lets outside air in continuously.
The production kitchen or bakehouse. Goal: maintaining an acceptable working temperature despite an oven, a fryer, a mixer, a dough sheeter. The load is massive, concentrated and almost constant during production hours — often overnight in a bakery. Workstations require a temperate environment for process reasons (dough proving, chocolate tempering) as much as for working conditions.
The stockroom and plant room. Goal: removing the heat from refrigeration units, refrigerated cabinets and cold rooms. This is not about comfort, it is about ventilation, and it is the point quotes most often overlook.
The three spaces share neither the same setpoint, nor the same operating schedule, nor the same hygiene constraints. Treating them with two identical split units guarantees that at least one of the three will break down.
The calculation nobody does: adding up process loads
In a home, sizing starts from glazed areas, insulation, orientation and the number of occupants. We set out that method in our article on calculating kW room by room. In a food shop, those factors become secondary. What dominates is internal heat gains.
| Heat source | Typical output released into the space |
|---|---|
| Deck oven or convection bakery oven | several kW continuously, even when well insulated |
| Integral refrigeration unit in a display case | roughly its entire absorbed electrical power |
| Refrigerated cabinet in an unventilated stockroom | 0.5 to 1.5 kW each |
| Older-generation display case lighting | 0.2 to 0.8 kW |
| Fryer, griddle, professional coffee machine | 1 to 4 kW during service hours |
| Customers at peak times | 80 to 120 W per person |
A poorly understood physical principle explains half of all failures: a self-contained refrigerated cabinet does not create cold, it moves heat around. Everything it removes from its products, plus its own electricity consumption, goes straight back into the room. A shop fitted with three self-contained display cases can therefore take on 4 to 6 kW of extra heat continuously — exactly what the air conditioner is supposed to be fighting.
That is why the first question in a serious technical survey of a food shop is not "how many square metres?" but "what equipment, what installed electrical power, what operating hours?". A reading of the distribution board and of the machines' rating plates is worth more than a floor measurement. A simple plug-in power meter on movable cabinets makes it possible to measure what the rating plates no longer tell you after ten years of use.
The bakehouse: cooling down is not air conditioning
The bakehouse is the space where mistakes cost the most. Three realities apply there.
A hot oven makes a living-room setpoint unreachable. Aiming for 22 °C in a bakehouse mid-bake is wishful thinking, even with a large machine: you burn out the compressor trying. The realistic goal is a controlled difference from outside (typically bringing 38–40 °C down to 27–28 °C during peak periods) and a correct temperature at sensitive workstations.
Ventilation comes before air conditioning. A properly sized bakehouse extraction hood with fresh-air make-up removes infinitely more heat than a split unit. If the extraction is undersized or the make-up air is missing, the shop goes into negative pressure, draws hot street air in under the door, and the sales-floor air conditioner runs for nothing. Many "air conditioning breakdowns" in food shops are in fact air-movement problems.
The equipment has to withstand the environment. Flour, cooking fats, sugary vapours: indoor unit heat exchangers get clogged within weeks. In a production kitchen, we favour units whose filters are accessible without dismantling, plus monthly cleaning carried out by the team with a simple air conditioner coil cleaner, on top of the refrigeration engineer's annual service. We described in detail which tasks you may do yourself and which to leave to a professional in our article on cleaning your air conditioning.
On the regulatory side, the employer remains required to assess and prevent risks linked to thermal environments. According to France's occupational safety institute, the INRS, above 30 °C for sedentary work and 28 °C for physical work, the health risk becomes significant; since the decree of 27 June 2025, the assessment of heat-related risks and the corresponding measures must appear explicitly in the single risk assessment document. A bakehouse at 40 °C in August is not an occupational inevitability, it is a documented prevention issue.
Sales floor: humidity before cold
In the shop, the real complaint is almost never "it's hot". It is:
- display cases that fog up, with the condensation hiding the products;
- pastries that go soft by late morning;
- chocolate that blooms or dulls;
- cheeses that sweat;
- labels and packaging that buckle.
All of these symptoms are humidity problems, not temperature problems. Summer air in the Paris region, laden with moisture, comes in through the door with every customer and condenses on every cold surface. The answer is not to lower the setpoint — which often makes condensation on refrigerated glazing worse — but to dehumidify the treated air and limit stray air infiltration.
In practice:
- choose units capable of operating at reduced airflow and low evaporating temperature, to dehumidify without over-cooling;
- fit the entrance with an air lock, a properly adjusted hot/cold air curtain, or at the very least a hydraulic door closer: a door left open 20 % of the time cancels out most of the air treatment;
- measure before deciding. A digital thermometer-hygrometer placed in the display area and another at the back of the shop cost a few tens of euros and will tell you in a week what three contradictory quotes fail to explain;
- do not confuse roles: a portable dehumidifier is no substitute for a properly designed machine, as we explained in our comparison of dehumidifier versus air conditioning.

Food hygiene: what the air conditioning must comply with
A food shop falls under the European hygiene package and its food safety management plan. Air conditioning becomes a piece of equipment to be documented, for three reasons.
The airflow must not blow onto uncovered food. An indoor unit aimed at a worktop, an open display case or a plating area dries out products and carries particles. You blow towards circulation areas, never onto food.
Condensate must be drained away and must never stagnate. A clogged indoor unit drain pan above a worktop is a critical point in the event of an inspection by the direction départementale de la protection des populations (departmental directorate for the protection of populations). Gravity drainage is preferable; where it is impossible, the condensate pump must be accessible and cleaned at every visit — it is the most frequent summer breakdown, covered in detail in our article on condensate drainage.
Servicing must be written down. Filter cleaning frequency, disinfection of heat exchangers and drain pans, leak testing of the refrigerant circuit: these operations belong in the food safety management plan, together with the contractor's certificates. Bear in mind that periodic leak testing is required by article R.543-99 of the Code de l'environnement (French Environment Code) from 5 tonnes of CO₂ equivalent of charge upwards, a threshold quickly exceeded by multi-split equipment or a commercial refrigeration unit. On air quality, the French health and safety agency ANSES recommends treating air-handling circuits primarily through cleanliness and air renewal rather than with disinfectant products sprayed blind.
Which technical set-up to choose
Here are the solutions we recommend depending on the configuration, for a Paris-region food shop of 40 to 150 m².
| Configuration | Suitable solution | Why |
|---|---|---|
| Shop only, 30–60 m², few self-contained display cases | Single or dual split, wall-mounted or ceiling cassette | Simple, repairable, controlled cost |
| Shop + production kitchen on staggered schedules | Two independent systems | A single shared unit creates day/night control conflicts |
| Production kitchen with oven and heavy load | Robust ceiling-mounted or ducted units + hood with make-up air | Ventilation does the heavy lifting, air conditioning completes it |
| Open floor plate of 80–150 m², suspended ceiling available | Ducted system with multiple returns | Even distribution, no airflow onto food |
| Stockroom with refrigerated cabinets | Thermostatically controlled mechanical extraction, sometimes a dedicated split | Remove condenser heat before trying to cool |
| Protected façade, inner courtyard, no outdoor space | Bespoke study, sometimes a monobloc unit | Façade constraints often dictate the final choice |
Two points to watch that come up in almost every project:
- the outdoor unit location. Between the shopfront, the building's courtyard, the first-floor neighbours' windows and the delivery area, the choice is rarely free. It determines the type of machine and the length of the pipe runs, and therefore the price;
- the available electrical capacity. Adding 10 to 15 kW of cooling to a distribution board already loaded with an oven, display cases and a utensil washer means checking the supply contract and the breaker ratings. A connected energy monitor on the main incoming supply lets you see the real power draw before ordering equipment.
Winter operation: the badly thought-out reversible trap
A food shop often heats itself. A bakehouse in production needs no heating; a north-facing glazed shop does. A reversible system therefore makes sense on the sales floor — provided it does not blow warm air onto refrigerated display cases, whose consumption would climb and whose products would suffer.
In practice, the zones are separated: reversible heating on the customer and till side, independent control on the production kitchen side, and no airflow directed at refrigerated cabinets. The winter efficiency principles we described for homes in our article on reversible air conditioning in heating mode apply here, with one difference: in a shop, a door opening all day long weighs more heavily than the machine's coefficient of performance.
Budget and timing: what we see in the Paris region
The ranges below reflect what we see on Paris-region projects, equipment and installation included, excluding major building works and hood works.
| Project | Observed range |
|---|---|
| Professional-grade single split in a 40 m² shop | €2,500 to €4,500 excl. VAT |
| Dual split, shop + stockroom | €4,500 to €8,000 excl. VAT |
| Ducted system on a 100 m² floor plate with suspended ceiling | €10,000 to €20,000 excl. VAT |
| Treating a heavily loaded production kitchen (AC + air return) | €8,000 to €18,000 excl. VAT |
| Annual servicing contract, multiple units | €300 to €900 excl. VAT per year |
The right time of year is autumn or winter, for three reasons: lead times for work are short, interruptions to trading can be negotiated outside the high season, and commissioning happens before the first heatwave. A shop that launches its project in June works under pressure, with the prices and compromises that come with it.
If you are starting from existing equipment installed by a predecessor, begin with an assessment: age, refrigerant, charge, condition of the heat exchangers, compliance of the drainage. Our air conditioning installation and servicing for businesses pages set out what a technical survey covers, and our article on the stages of an installation describes the full process.
Key takeaways
- A food shop accumulates internal heat gains that far exceed solar gains: sizing starts from the machines, not the floor area.
- Self-contained refrigerated cabinets release their heat into the room: count them twice, once as a heat source, once as equipment to protect.
- In the shop, the real battle is humidity and air coming in through the door, not the temperature setpoint.
- In a production kitchen, the hood and compensated fresh air do more than any split unit; air conditioning completes the job, it does not replace it.
- Air conditioning and food hygiene overlap: no airflow onto food, flawless condensate drainage, servicing written into the food safety management plan.
Do you run a bakery, a butcher's, a cheese shop or a production kitchen in the Paris region, and your installation can't cope with summer? Request a technical survey: we record the installed capacities, the existing air movement and the façade constraints before proposing a design — not the other way round.